3 November 2026
Roof Windows And Skylights In Croydon: Costs, Planning And Stopping The Leaks
Roof windows, rooflights and sun tunnels in Croydon: why they leak, fitting them in plain tile and concrete roofs, planning rules and 2026 guide prices.
A hole in the roof with glass in it is the easiest way to get daylight into a loft, a landing or a dark back bedroom. It is also one of the places a Croydon roof is most likely to let water in. Most roof windows here are fitted without a planning application, provided the glass sits within 150mm of the roof slope, but Croydon Council lists 21 conservation areas, and one of them in Addiscombe takes away that right altogether. The cost runs from a few hundred pounds for a sun tunnel to well over £3,000 for a conservation rooflight in a new opening. And whether the window stays dry for thirty years depends less on the brand than on how the tiles around it were cut, lapped and dressed. Here is how the three types differ, where each kind of Croydon roof makes the job harder, and what people are paying in 2026.
Roof window, fixed rooflight or sun tunnel?
Three products get called “skylights”, and they do different jobs. A roof window is the one most people picture: a timber or white-coated frame set into the slope with a sash that pivots so you can open it, clean the outside and get air through the room. It is the usual choice for a loft room, a converted attic bedroom or a bathroom under the eaves. A fixed rooflight doesn’t open. That makes it simpler and slightly cheaper, and it suits stairwells and spaces you only want lit. The slim conservation rooflights, with a dark frame and a central glazing bar, are made to look like the old cast-iron ones on Victorian roofs.
A sun tunnel is the odd one out. A small dome on the roof feeds a mirrored tube down through the loft to a round diffuser in a ceiling. You can’t see out of it or open it, but it puts daylight into a room that has no roof slope above it. The classic case is the windowless landing in the middle of a 1930s semi. Common sizes are 250mm and 350mm across, and the larger one is worth having if the tube has to bend.
If you already have one of these and water is coming in around it, that is a repair, not a new installation. Our roof leak repairs page covers how we trace that, and the rest of this post explains what usually turns out to be the cause.
Leak or condensation? Reading the stain
Before anyone climbs a ladder, work out what kind of wet you have. In winter, a lot of “leaking Velux” worries turn out to be condensation, and the fix for that is nothing like the fix for a leak.
Condensation turns up on cold, still mornings, mostly in bathrooms and bedrooms where people breathe and shower all night with the window shut. The water forms on the inside of the glass and on the cold frame, runs down, and soaks the bottom edge of the plaster lining. Over a few winters it rots the bottom rail of an old pine frame. A real leak keeps time with the weather instead. It shows after wind-driven rain from the south-west, or after a summer cloudburst when the channel at the head of the window overflows. Usually the stain starts at a top corner or runs down one side of the reveal, well away from the bottom of the glass.
The third possibility is misting between the two panes. That means the sealed glazing unit has failed. It won’t make a ceiling wet, but it won’t clear either, and the only cure is a new glazing unit or a new sash.
Croydon’s trees cause one problem of their own. Through Purley, Kenley, Sanderstead and Shirley, leaves and seed pods collect in the gap above a roof window every autumn. They dam the water so it backs up under the top of the flashing. A window that only leaks from October to December, and only on the slope under the oak, has probably told you its cause already.
Croydon’s three main roofs, and what each does to the job
The window is the same product whichever roof it goes in. The work around it is not.
Victorian and Edwardian houses with clay plain tiles
Plenty of the older houses north of the town centre are slated, but the Edwardian streets and the Arts and Crafts houses further south are often covered in small clay plain tiles, laid double-lapped on a steep pitch. Each course is only a few inches deep, so a tidy job needs tile-and-a-half tiles at the sides of the window rather than slivers of cut tile, and a soaker slipped under every course. A good number went on with nothing underneath but the battens, since roofing felt only became usual after the war. Cutting a hole in one means adding a collar of underlay around the opening, fixed so that it drains onto the battens and doesn’t sit in a pocket behind the window.
1930s semis in Shirley, Selsdon, Sanderstead and Coulsdon
The interwar semis usually have hipped roofs, so the rear slope narrows towards the top and the side slopes are short. A window has to sit low enough to clear the hip rafters, and anything wider than the gap between two rafters means cutting one and trimming either side. A lot of these houses were re-roofed in concrete tiles decades ago, so check what is actually on yours before ordering a flashing kit. Don’t go by what the street had in 1934.
Post-war houses with concrete interlocking tiles
On the estates of New Addington and Fieldway, and on plenty of re-roofed houses elsewhere, the covering is large interlocking concrete tiles. They are quick to cut around, but a tile cut down the side of a window loses its interlock. It needs a clip or a mechanical fixing, or the first big gale will lift it. The lead apron along the bottom of the flashing also has to be dressed down into every trough of the tile profile below it. An apron left sitting flat across the tops of the waves is a very common fault on these roofs.
The flashing kit decides whether it leaks
The glass and the frame almost never let water in. The flashing is the set of metal pieces that sits between the frame and the tiles, and that is where the problems are. Manufacturers make different kits for different coverings. Velux, for example, sells a plain-tile kit (EDP) built around separate soakers, a standard kit for profiled tiles (EDW), and a recessed kit (EDJ) that sets the window lower into the roof. The wrong kit on the right roof is a slow leak waiting for the right storm.
The usual faults:
- A profiled-tile kit fitted to a plain-tile roof, so the side pieces sit over the tiles instead of being interleaved with them.
- Tiles at the head of the window not cut back far enough, leaving no clear gutter for water to run along and off the sides.
- The underlay collar missing, so water that gets past the tiles in a storm runs straight onto the lining.
- No insulation collar around the frame, which gives you a cold strip inside the reveal and a line of condensation right where it marks the paint.
- A previous “repair” made by squeezing sealant into the joints. It holds for a season, then cracks and traps water where it does the most harm.
If the window itself is sound, re-flashing it is often the better buy: lift the tiles around it, fit the correct kit and relay them. If the frame is rotten or the glass has failed, though, it makes sense to replace the window and the flashing together while the tiles are already off.
Replacing an old roof window in the same opening
Lofts converted in the 1980s and 1990s often still have their original pine roof windows, and many of those are near the end of their life. Signs to look for are a bottom rail gone black and soft, a sash that won’t close tight, hinges that grind, or glass that has misted between the panes.
Usually the hole can stay as it is. The big manufacturers still make windows to fit openings cut decades ago. The size code is printed on a small data plate on the frame, which you can see when the sash is open, and that is the first thing to photograph before you ask for a price. A like-for-like replacement keeps the same rafters and trimmers, so most of the job happens from inside. It goes in with a new flashing kit and insulation collar, and the lining gets made good afterwards.
Choose the frame finish for the room. Pine is fine in a bedroom or study. In a bathroom or kitchen, a white polyurethane-coated frame shrugs off the steam that rots timber. If the window is the escape route from a loft room, check before ordering that the replacement still opens wide enough. Some newer styles open differently from the one you have.
Planning permission: permitted development and Croydon’s exceptions
Most roof windows on houses don’t need an application. The national permitted development rules allow them if three conditions are met. The glass and frame must project no more than 150mm beyond the plane of the roof slope. Nothing can sit higher than the highest part of the roof. And a window on a side-facing slope must be obscure glazed and fixed shut, unless the opening part is more than 1.7 metres above the floor of the room. The Planning Portal’s interactive guide to roof windows sets these out with diagrams.
People often assume a front slope is off limits. Under the national rules it isn’t: a flush roof window facing the street is treated the same as one at the back. Whether it looks right on a terrace of matching Victorian roofs is a separate question, and on those streets a conservation-style rooflight is usually the better neighbour.
Croydon’s exceptions are where it matters. The Chatsworth Road conservation area in Addiscombe has an Article 4 direction that removes permitted development for all alterations to a house’s roof, so there even one rooflight on the back needs an application. Other directions in the borough cover different things, and Croydon Council’s Article 4 directions page links to each one. Flats and maisonettes have no permitted development rights for roof alterations at all, which catches out a lot of owners of converted Victorian houses in Thornton Heath, South Norwood and Selhurst. Listed buildings need listed building consent whatever the window. And if you are not sure, a Lawful Development Certificate gives you proof that the work didn’t need permission. That is useful when you come to sell.
Building regulations: who signs it off
Planning and building regulations are separate questions, and the second one applies more often. Cutting a new opening means cutting or trimming rafters. That is a structural alteration, and it normally needs building control involved, with an engineer’s note on the trimming if the window is wide or the roof is already carrying a dormer.
Replacing a whole roof window, frame and all, in an existing opening counts as a “controlled fitting”. The new window has to meet the heat loss limits in Approved Document L of the building regulations, which any current double-glazed roof window from a mainstream maker will. The installer either self-certifies through a competent person scheme such as FENSA or CERTASS, or you notify building control yourself. Swapping just a glazing unit or a sash is classed as a repair and sits outside both.
If a roof window serves a habitable loft room, Part B of the regulations may need it to work as an escape window. That means a clear opening of at least 0.33 square metres, at least 450mm high and 450mm wide, with the bottom of the opening no more than 1.1 metres above the floor. Our post on loft conversion roofs in Croydon covers the dormer and structural side of a full conversion, which is a bigger job than adding a window.
What roof windows cost in Croydon in 2026
These are guide prices for typical Croydon houses, including VAT, for standard sizes on a pitched roof that can be reached from inside or from a roof ladder. They are not quotes. Access, the roof covering and what the inside lining needs will move them.
| Job | Guide price |
|---|---|
| Sun tunnel to a landing or bathroom, fitted | £550 to £1,100 |
| Re-flashing and re-tiling around an existing roof window | £350 to £750 |
| New glazing unit or sash only | £350 to £800 |
| Like-for-like roof window replacement with new flashing | £950 to £1,800 |
| New roof window in a new opening, per window | £1,400 to £2,600 |
| Second window on the same visit | £900 to £1,600 |
| Conservation rooflight in a new opening | £1,900 to £3,500 |
| Plastering, lining and decorating the new reveal | £300 to £700 |
A few things push the price up. A front slope over a busy road, or a three-storey Victorian house, may need a scaffold or a tower, which can add several hundred pounds. Plain clay tiles take longer to work around than concrete interlocks, so expect the top half of each range. Building control fees and any structural engineer’s note come on top for new openings.
South London has no shortage of window fitters or roofers. Finding one who will do both properly is harder: someone who fits the frame and then relays the tiles around it the way the roof needs. Ask any installer which flashing kit they plan to use and how they will handle the tiles at the sides. A clear answer is a good sign.
Get a free quote for a roof window repair or replacement in Croydon
Frequently asked questions
Do I need planning permission for a roof window in Croydon?
Usually not, if the house is a house rather than a flat. Under permitted development a roof window can go in as long as it stands no more than 150mm proud of the roof slope, sits below the highest part of the roof, and any window on a side-facing slope is obscure glazed and fixed shut unless the opening part is more than 1.7 metres above the floor inside. Flats and maisonettes have no permitted development rights for this, listed buildings need listed building consent, and in the Chatsworth Road conservation area in Addiscombe an Article 4 direction means every roof alteration needs an application.
Is my roof window leaking, or is it condensation?
Look at when it happens. Condensation shows up on cold, still mornings, often in a bathroom or a bedroom, and runs down the inside of the glass onto the bottom of the lining. A leak follows the rain, usually wind-driven rain or a heavy downpour, and tends to appear at the top corners or down one side of the reveal. Water trapped between the two panes of glass is neither: it means the sealed glazing unit has failed and needs replacing.
Can an old roof window be replaced without making the hole bigger?
Normally, yes. The main manufacturers still make windows to fit openings cut decades ago, and the size code is printed on a data plate on the frame, which you can see with the sash open. A like-for-like swap uses the same opening and the same rafters, and usually goes in with a new flashing kit and an insulation collar. Replacing the whole window, frame included, is a controlled fitting under the building regulations, so the installer should either be registered with a competent person scheme or notify building control.
Is a sun tunnel worth it on a 1930s semi?
For the windowless landing or the internal bathroom that so many interwar semis have, often yes. A sun tunnel runs a mirrored tube from a small dome on the roof, through the loft, to a diffuser in the ceiling, so you get daylight without opening up a room in the roof. It costs a good deal less than a roof window. The catch is that it gives light only, with no view and no ventilation, and the run through the loft has to be short and fairly straight to give much light.
Free roof survey and a fixed written quote
Anywhere in Croydon and the surrounding CR postcodes. No call-out fee.